KFG Electrically operated pumps
Lubrication System Type:
Progressive lubrication system
The electrically operated KFG pump includes a drive shaft with an eccentric that drives up to three pump elements. It is comprised of four main components: housing with pump elements, reservoir with fill-level monitoring, internal control units and attachments. The pump is available in eight sizes and two variants forstationary use or with grease follower plate technology for utilization in any position. A variety of attachments permit reservoir filling, protect the pump (pressure-limitation valve) or enable the uncomplicated connection of the pump to a centralized lubrication system.
Features and Benefits:
Durable and reliable components designed for extreme conditions (with positively driven pump elements) Versatile: can be used with single-line and progressive systems Safe: through fill-level monitoring, lubrication system monitoring, pressure relief and control unit Pin code protection of control unit available Options: Top filling, several electronic options, Can bus
We offer the following Electrically operated pumps variants.
KFGX1FXXXXXX99+924, KFGS1FXXXXXXEB+924, KFGX3FXXXXXX99+924, KFGS3FXXXXXXEB+924, KFGS1FX1XXXXEB+924, KFGS1FXXXXXXEB+912, KFGS3FX1XXXXEB+924, KFGX1FX1XXXX99+924, KFGS1FAXXXXXEB+924, KFGS1FXXXXXXGD+924, KFGX1FXXXXXX99+912, KFGS3FXXAXXHEB+924, KFGS3FX1XXXXEB+912, KFGS1MX1XXXXEB+486, KFGX1MX2XXXX99+924, KFGS1FAXXXXXEB+912, KFGX1MXXXXXX99+924, KFGS1FX1XXXXEB+912, KFGX1MX3XXXX99+924, KFGX3MX1XXXX99+924, KFGS3FAXXXXXEB+924, KFGS3FXXXXXXEB+912, KFGS3MXXXXXXEB+486, KFGS3MXXXXXXEB+924, KFGS3MX1XXXXEB+486, KFGX1MX1AXXD99+486, KFGX1FAXXXXX99+912, KFGS1FXXAXXHEB+924, KFGS3MXXXXAHEB+924, KFGS1MXXXXXXEB+486, KFGX3MX2XXXX99+924, KFGS5FX1XXXXEB+924, KFGS1FXXXXXXAI+924, KFGX1MX3XXXX99+486, KFGS3MXXAXXHEB+924, KFGS3MX1XXXXEB+924, KFGS3FA1XXXXGO+924, KFGX1FX1AXXH99+924, KFGX3MX3AXXH99+924,
Technical Specifications:
Function principle: Electrically operated piston pump
Number of lubricant outlets: up to 3 pump elements
Pump outlet No. 1 - Metering quantity - Metric: 0,8; 1,3; 1,8; 2,5; 5,0 cm³/min
Pump outlet No. 2 -Metering quantity - Metric 2: 0,8; 1,3; 1,8; 2,5; 5,0 cm³/min
Pump outlet No. 3 -Metering quantity - Metric: 0,8; 1,3; 1,8; 2,5; 5,0 cm³/min
Inlet: x
Outlet: x
Lubricant: grease: up to NLGI 2 compatible with plastics, NBR elastomers, copper and copper alloys
Number of lubricant outlets: up to 3 pump elements
Metering quantity per pump element - Metric: 0,8; 1,3; 1,8; 2,5; 5,0 cm³/min
Capacity of the reservoir - Metric: 2; 4; 6; 8; 10; 12; 15; 20 kg
Main line connection: M 14 × 1,5 female thread
Operating voltage: 12 V DC; 24 V DC; 230 (90-264) V AC; (± 10%)
Operating pressure - Metric: 200-300 bar
Operating temperature Celcius: with spring-return pump element –25 to +70 °C; with posit. driven pump element –30 to +70 °C
Control Unit: without control unit; with control unit IG502-2-l; with control unit LC 502
Dimensions Metric: min. 266 × 208 × 229 mm; max. 268 × 227 × 1 170 mm
Mounting position: with follower plate: any, also rotating applications without follower plate: upright
Fill level monitoring: without fill level monitoring; mechanical (minimum); mechanical with signal smoothing (maximum); capacitive (minimum)
Filled with Lubricant: without Lubricant; filed with grease NLGI Class 2; customised grease